Setting up
AIR CONDITIONING WITH INSTALLATION
For more efficient use Pinguino can also be
semi-permanently installed
Fit the flange supplied to the hole.
Fix the hose to the coupling on the
back of the unit (figure A).
Attach the end of the tube to the flan-
ge as shown in the figure E.
16
17
17
16
To install, proceed as follows:
Make a hole in an outside wall or through
the pane of a window. Check the height
and dimensions given in figure D
30 cm
30 cm
MAX115 cm
MIN 50 cm
When the hose is not attached, close
the hole with the bung on the flange .
NOTE:
When the unit is installed semi-permanently,
we recommend leaving a door slightly open
(1 cm is enough) to ensure an adequate
exchange of air.
16
17
in a window
pane
in the wall: for
optimum results,
insulate the sec-
tion of the wall
with suitable
insulating mate-
rial.
in the
wood sill of
a window
D
DEHUMIDIFICATION
Position the appliance in the room without
inserting the hose; in this way the dehumidi-
fied air will exhaust directly into the room.
E